Manufacturers of Process
Control Instruments
We are an eminent Manufacturer and exporters of Process Control Instruments. Our Quality Instrumentation Products have already remained TIME PROVEN.
5 Digit Indicators & Controllers - 805
 
 
horizontal
7661
( 96*48 type )
 
horizontal
7643
( 96*96 type )
 
horizontal
7680
Next to Yellow in spec803 ( 96*96 type )7680 ( GROUP )
 
 
spadcer pdf spadcer
 
  • Rugged and Time proven designs.
  • Universal / Predefined type inputs.
  • Up based & Fully configurable.
  • Supports wide input types & ranges
  • Gives max. 4 on/off outputs.
  • Retransmission output on PV.
  • Transmitter P.S. @ 24V DC.
  • Various sizes / Mountings / Enclosures supported.
  • RS-485 Comm. O/P provided.
 
MODEL 805 � MICROPROCESSOR BASED SIGNAL INDICATORS / CONTROLLERS

( High Precision 5 digit and Fully configurable )

 

Introduction


Pantech's Programmable Microprocessor based Indicator cum Controller, model 805 is an ideal instrument for providing indication as well as controlling set points to various processes. This model specially indicates the process value to the resolution of maximum 5 digits i.e high precisions. It is designed to accept various process inputs ( Current, Voltage, RTD, Thermocouples, Resistances ) simultaneously i.e in UNIVERSAL manner or any one of these in PREDEFINED manner. When UNIVERSAL manner, The user can configure from the front keys only to select any one of the input automatically. The user can also configure to set the range of linear inputs or calibrate the instrument without openint it. The model 805 can give maximum 4 relay outputs. All the contact output related specs like � SETPOINT, ALARM TYPE, HYSTERISIS � can be configured easily by the front panel keys itself. Retransmission facility is of course provided with all possible configurations allowed by front keys as usual. The instrument can be optionally equipped with serial communication facility to operate on MODBUS RTU protocols. Single level password is there to keep the settings and configurations intact for the right user only.

Low drift precession components are used for long term accuracy of the instruments. All instruments undergo a burn-in for better reliability.The instrument is available in different formats and sizes. Information regarding specification and size is given below.

 
Specifications
 

Inputs ( & Display range )

  1. Current, 4– 0 mA DC/ 0–20 mA DC ( -19999 to 59999)

  2. Voltage, 1–5V/0–10V (-19999 to 59999 )

  3. RTD Pt 100 – 3 wire ( -100.0 to 600.0 C )

  4. T/C Type J (-100.0 to 800.0 C )

  5. T/C Type K (0 to 1200.0 C )

  6. T/C Type R (0 to 1760.0 C )

  7. T/C Type S (0 to 1700.0 C )

  8. T/C Type T (-100.0 to 400.0 C )

  9. T/C Type B ( 450.0 to 1820.0 C )

  10. T/C Type E ( -100.0 to 1000.0 C )

  11. Ohms-0-1K ohms ( -19999 to 59999 )

  12. mV DC

  13. UNIVERSAL 1 – Containing 1…8

  14. UNIVERSAL 2 – Containing 1…12

  15. Pulse train input. ( Pulse of 12 V DC )

  16. 10 to 10 V DC / -mV to mV DC ( -19999to59999)

  17. RTD – Cu 53

  18. Special type of inputs of any V/Current/Resistance
    ( However on factory confirmation only )
    Decimal point configurable

Input impedance

200 KΩ for Voltage, mV & T/C inputs upto 250 ohms for current inputs

Display resolution

5 digit

Display accuracy

+/- 0.1% of span

Alarms

Maximum 4 nos. of potential free contacts. xxxxxxxxxxx

Analog output

Maximum 2 nos. of any of below

  1. Isolated / Non Isolated 4 – 20 mA DC

  2. Isolated / Non Isolated 0-10 V DC

Other types on factory confirmations

Analog output load capability

800Ω maximum for current outputs6

Output accuracy

+/- 0.1% of span

Serial output with open protocol

  1. RS232 With modbus RTU protocol

  2. RS485 with modbus RTU protocol

Note: Any other protocol on demand
 

Transmitter power

24 V DC for current inputs

10/12 V DC ( in case of Load cell / Proximity application )

Specials

Power supply

  1. 24 V DC

  2. 110 V AC, 50 Hz, +/- 10%

  3. 230 V AC, 50 Hz, +/- 10%

  4. 90-270 V AC, 50 Hz. – SMPS

  5. Specials on factory confirmations

Security

Single level Password protected

Contact ratings

230 V AC, 5 Amps.

Power consumption

3 VA max.

Ambient temperature

0 – 50° C.

Storage temperature

0 – 70° C.

Humidity

90% RH (non-condensing)

Enclosures

Weatherproof, Flameproof and all other standard types

Mounting

Panel / Wall / Field / Dinrail / Eurocard

Dimensions

96*96 / 96*48 / 72*72 / SPECIALS

*All config/calibration from front keys only


Following table describes the availability of several models with the company right now. A general preview is only presented to the user. The dimensional and display sizes are the relational virtues of each other and hence the user is always requested to clarify the specifications of instrument with the factory prior to placement of the order.

 

On confirmation with factory, changes of all types in all specifications is possible.

 

Model

Mounting & Dimension in mm (H * W)

Inputs

Power

Alarms

Retrans-mission

Process value Display resolution

Process value Display size “

Isolated or Not-Isolated

805

Panel

48*96

All

All

Max.2

Max. 1

5 digit

0.25”

72*72

All

All

Max.2

Max. 1

5

0.25/0.5”

96*96

All

All

Max.4

Max. 2

5

0.25/0.5”

144*72

All

All

Max.4

Max. 2

5

0.25/0.5/1”

72*144

All

All

Max.4

Max. 2

5

0.25/0.5/1”






5


Din Rail

70*100 max

All

All

Max. 4

Max. 2

5

0.25/0.5”

Euro

Std. or as req

All

All

Max. 4

Max. 2

5

0.25/0.5”

Wall

As required or Optimum possible

All

All

Max. 4

Yes

5

0.25” to 6”

 
 
Ordering Information ( 12 digits )
 

Please confirm the availability of the model by cross checking the table mentioned on the backside.

Basic Model No. (Specified by first 3 digits)

805 - Signal Ind. cum Controller Microprocessor based and Fully configurable

Enclosure / Mounting (Specified by letter following 3 digits)

P - Weatherproof - Panel

R - Weatherproof -Din Rail

E - Weatherproof - Euro card

W - Weatherproof - Wall

F - Flame proof – Wall / Field

I - IP65 grades – Wall / Field

S - Specials

Input (Specified by first digit following the letter) 1 - mA DC signal input

1 - mA DC signal input

2 - V DC signal input

3 - RTD type

4 - Thermocouple

5 - Resistances

U - UNIVERSAL1

V - UNIVERSAL2

S - SPECIALS

Power Option (Specified by the next digit / letter)

1 - 24 V DC

2 - 110 V AC

3 - 230 V AC

4 - 90-270 V AC – SMPS

S - SPECIALS

 

Alarms Option (Specified by the next digit / letter)

0 - None

1 - 1 no. of alarm

2 - 2 no. of alarms

3 - 3 no. of alarms

4 - 4 no. of alarms

Analog O/P Option (Specified by the next digit / letter)

0 - None

1 - 1 no. mA/V DC isolated

2 - 2 no. mA/V DC isolated

3 - 1 no. mA/V DC N. I.

4 - 2 no. mA/V DC N.I

S - Any other type of outptus

Display Resolution (Specified by the next digit / letter)

1 - 2/3 digit

2 - 4 digit

Communication output
( Specified by the next digit / letter )

0 - None

1 - YES