Inputs ( & Display range )
Current, 4– 0 mA DC/ 0–20 mA DC ( -19999 to 59999)
-
Voltage, 1–5V/0–10V (-19999 to 59999 )
-
RTD Pt 100 – 3 wire ( -100.0 to 600.0 C )
-
T/C Type J (-100.0 to 800.0 C )
-
T/C Type K (0 to 1200.0 C )
-
T/C Type R (0 to 1760.0 C )
-
T/C Type S (0 to 1700.0 C )
-
T/C Type T (-100.0 to 400.0 C )
-
T/C Type B ( 450.0 to 1820.0 C )
-
T/C Type E ( -100.0 to 1000.0 C )
-
Ohms-0-1K ohms ( -19999 to 59999 )
-
mV DC
-
UNIVERSAL 1 – Containing 1…8
-
UNIVERSAL 2 – Containing 1…12
-
Pulse train input. ( Pulse of 12 V DC )
-
–10 to 10 V DC / -mV to mV DC ( -19999to59999)
-
RTD – Cu 53
-
Special type of inputs of any V/Current/Resistance
( However on factory confirmation only )
Decimal point configurable
Input impedance
200 KΩ for Voltage, mV & T/C inputs
upto 250 ohms for current inputs
Display resolution
5 digit
Display accuracy
+/- 0.1% of span
Alarms
Maximum 4 nos. of potential free contacts. xxxxxxxxxxx
Analog output
Maximum 2 nos. of any of below
Isolated / Non Isolated 4 – 20 mA DC
-
Isolated / Non Isolated 0-10 V DC
Other types on factory confirmations
Analog output load capability
800Ω maximum for current outputs6
Output accuracy
+/- 0.1% of span
Serial output with open protocol
-
RS232 With modbus RTU protocol
-
RS485 with modbus RTU protocol
Note: Any other protocol on demand |
|
Transmitter power
24 V DC for current inputs
10/12 V DC ( in case of Load cell / Proximity application )
Specials
Power supply
-
24 V DC
-
110 V AC, 50 Hz, +/- 10%
-
230 V AC, 50 Hz, +/- 10%
-
90-270 V AC, 50 Hz. – SMPS
-
Specials on factory confirmations
Security
Single level Password protected
Contact ratings
230 V AC, 5 Amps.
Power consumption
3 VA max.
Ambient temperature
0 – 50° C.
Storage temperature
0 – 70° C.
Humidity
90% RH (non-condensing)
Enclosures
Weatherproof, Flameproof and all other standard types
Mounting
Panel / Wall / Field / Dinrail / Eurocard
Dimensions
96*96 / 96*48 / 72*72 / SPECIALS
*All config/calibration from front keys only
Following table describes the availability of several models with the company right now. A general preview is only presented to the user. The dimensional and display sizes are the relational virtues of each other and hence the user is always requested to clarify the specifications of instrument with the factory prior to placement of the order.
On confirmation with factory, changes of all types in all specifications is possible. |