Inputs per channel ( max. n nos. )
-
Current, 4 – 20 mA DC/ 0 – 20 mA DC ( -1999 to 9999)
-
Voltage, 1 – 5V/0 – 10V (-1999 to 9999 )
-
RTD Pt 100 – 3 wire ( -100.0 to 600.0 C )
-
T/C Type J (-100 to 800 C )
-
T/C Type K (0 to 1200 C )
-
T/C Type R (0 to 1760 C )
-
T/C Type S (0 to 1700 C )
-
T/C Type T (-100 to 400 C )
-
T/C Type B ( 450 to 1820 C )
-
T/C Type E ( -100 to 1000 C )
-
T/C Type C ( 0 to 2315 C )
-
Ohms-0-10K ohms ( -1999 to 9999 )
-
mV DC
-
UNIVERSAL type 1 – 1…8 of above
-
UNIVERSAL type 2 – 1…13 of above
-
0-1 / 0-5 Ampere
-
Pulse train input. ( open collector type )
-
–10 to 10 V DC / -mV to mV DC ( -1999to9999)
-
RTD – Cu 53 ( -100 to 200 C )
-
Special type of inputs of any V/Current/Resistance
( However on factory confirmation only )
Input impedance
200 KΩ for Voltage, mV & T/C inputs
upto 250 ohms for current inputs
Display resolution
4 digit ( -1999 to 9999 ) Per channel
Display to show input PV
Display accuracy
+/- 0.1% of span
Corresponding outputs ( equals to no. of inputs )
-
Isolated / Non Isolated 4 – 20 mA DC
-
Isolated / Non Isolated 0-10 V DC
-
Other types on factory confirmations
Analog output load capability
800 maximum for current outputs
Output fine tune
By front keys only
Output accuracy
+/- 0.1% of span
Serial output with open protocol
-
RS232 With modbus RTU protocol
-
RS485 with modbus RTU protocol
Note: Any other protocol on demand |
|
ransmitter power
n*24 V DC for current inputs
Power supply
-
24 V DC
-
110 V AC, 50 Hz, +/- 10%
-
230 V AC, 50 Hz, +/- 10%
-
90-270 V AC, 50 Hz. – SMPS
-
Specials on factory confirmations
Security
Single level Password protected
Contact ratings
230 V AC, 5 Amps.
Power consumption
3 VA max.
Cold junction compensation
Built in for T/C input.
Ambient temperature
0 – 50° C.
Storage temperature
0 – 70° C.
Humidity
90% RH (non-condensing)
Enclosures
Weatherproof, Flameproof and all other standard types
Mounting
Panel / Wall / Field
Dimensions
Standard and Specials
*All config/calibration from front keys only
-
Following table describes the availability of several models with the company right now. A general preview is only presented to the user. The dimensional and display sizes are the relational virtues of each other and hence the user is always requested to clarify the specifications of instrument with the factory prior to placement of the order.
-
On confirmation with factory, changes of all types in all specifications is possible.
|